Showing results: 46 - 60 of 71 items found.
-
Macken Instruments, Inc
The Macken Instruments, Inc., Digital Laser Power Probe is a completely portable, easy-to-use calorimeter type power meter. The instrument consists of two components: a microprocessor-based digital meter and a probe head.
-
CLV-2534 -
Polytec GmbH
The new all-in-one CLV-2534 Compact Laser Vibrometer is made up of a rack-mountable 19?? controller supplying laser power to the sensor head via a fiber optical cable. Both compact and flexible in application, surface vibration in velocity and displacement are measured with high precision and low noise in a bandwidth of 3.2 MHz at 10 m/s maximum velocity.
-
mks Ophir
This scanning slit M² measurement system accurately analyzes lasers with wavelengths from UV to Far Infrared with its silicon, germanium, or pyroelectric head. It features a compact portable design, immediate results, ISO compliant measurements, and operates in CW or kHz Pulsed modes which makes it ideal for comprehensive analysis of lasers of most wavelengths.
-
10780C -
Keysight Technologies
The Keysight 10780C is a highly-sensitive, lowest-cost Keysight receiver used with laser interferometer positioning systems. One receiver is used per measurement axis (including wavelength tracker). Configured with Keysight electronics, laser heads, cables and optics, the Keysight 10780C receiver allows you tailor a precise positioning system for your exact application requirements.
-
Clamir -
New Infrared Technologies
*Continuous monitoring of melt pool dynamics and geometry.*Ensures quality and repeatability.*Compatible with most laser heads.*Compatible with a wide range of materials.*Easy mechanical integration.*Quick configuration.*Helps to reduce CO2 emissions.
-
Macken Instruments, Inc
Conical Head Power Probes are used to measure high power density CO2 laser beams which may damage the standard flat surfaced Power Probes. The conical absorbing cavity exhibits a high heat dissipation.
-
PIXEA -
AUREA Technology
The PIXEA is a high-quality laser system for OEM and R&D applications generating ultra-short optical pulses by using gain-switched laser diode technologies. The laser features high-quality picosecond laser pulses with no satellite pulses and minimize pulse tail. The PIXEA series offer a large variety of centered wavelengths between 375 nm and 2 um. The pulse duration down to 20 ps is optimized for each wavelength. The system is based in two modules or one module, the laser head and the dedicated Control Unit including the GUI software. Different optical output options are available, including free space collimating optics and fiber coupled.
-
TAC-L -
Dwyer Instruments Inc.
Model TAC-L Portable Digital Tachometer measures rotational speed either by contacting a rotatable head to the shaft of the object, or using photo sensor to detect the reflections from the laser. The laser target can record from a distance of up to 20 inches and gives a more accurate measurement than LED targeting. Model TAC-L includes a large LCD with a backlight for use in dark areas.
-
LS-500 -
Panasonic Industrial Devices Sales Company of America
The LS-500 Series Amplifier-Separated Type Digital Laser Sensor offers high-class Laser Sensors able to detect very small objects with a processing speed of down to 60µs. The new full stainless steel M6 housing is robust and optimally suited for applications in harsh environments. The unique controller can handle Thru-Beam, Diffuse Reflection and Retroreflection Laser Sensor heads. All Sensors are equipped with two digital outputs, and cable-type Sensors offer an additional analog output, opening new dimensions in the detection of small objects.
-
Duma Optronics LTD
The M2 factor wil define the beam propagation characteristics compared to ideal Gaussian beam propagation. According to ISO Standard 11146 rightfully offers the laser beam characterization as "M2 times diffraction limited beam", as such, a perfect beam will have an M2 of 1. 1 will be the best achievable value and no beam could have an M2 less than 1. Our conceptual design is based on sub-assemblies allowing to change the sensing head in the M2 device, offering multiple wavelengths heads up to 2.7 microns from deep UV (knife-edge technology) and camera based technology with built-in automatic filter wheel for adjustment. For focused beams, the same measuring head could be attached to a device for meauring highly divergent or highly convergent beams - FocusGage-BA, wherein the Laser Analyzing Electronic Autocollimator offers the capability of divergence measurement with Coming Soon M2 definition. M2Beam is the cornerstone of those measuring devices.
-
NanoScan -
mks Ophir
Measure your beam as never before with the NanoScan™ beam profiler. The advantage of scanning slit beam profiling is sub-micron precision for measuring beam position and size. Scan head configurations include Silicon, Germanium, and Pyroelectric versions for a wide range of wavelengths and laser power levels. The NanoScan software is available in two versions: Standard and Professional, and includes an extensive set of ISO quantitative measurements, an M2 Wizard, and the ability to measure laser power.
-
Model PECVD-60-M -
TEK-VAC INDUSTRIES Inc.
Retrofittable with RF-DC-Laser Ablation Modules. High Temperature Substrate Heating, 4" Diameter. High Power Magnetron Head, 600W Microprocessor Temperature Control. Standard Model equipped to handle four gas inputs, expandable. Adaptable for RF or DC Plasma. Top Loading, Compact Footprint. Broad Operating Pressure Range (10-4 to 760 torr).
-
10713D -
Keysight Technologies
The Keysight 10713D is one component of a family of measurement optics that tailor interferometer systems for the physical layout and measurement requirements of individual applications. Configured with appropriate laser head and system electronics, the optics are part of a precise positioning system that improves product quality, increases yields, and facilitates manufacture of precision products.
-
LP-RV SERIES -
Panasonic Industrial Devices Sales Company of America
The LP-RV Series FAYb Laser Marker features:- Short Pulse 20W Fiber Laser Offers Excellent Mark Contrast On Difficult To Mark Plastics And Various Other Materials- Optional EtherNET/IP Or ProfiNET Interface Adaptor Card- Modular Laser Oscillator System Makes Servicing In The Field Possible - Direct Connection To Panasonic PV230 Vision System For Mark Verification, Auto-Targeting, And Other Machine Vision Functions- Compact IP64-Rated Marking Head For Use In Harsh Environments- Compliant With FDA Regulations, GB Standard, KC Mark, Machinery Directive (Declaration of Incorporation), EMC Directive, RoHS Directive
-
OMM-6810B -
Newport Electronics
The OMM-6810B is a power and wavelength meter capable of simultaneously measuring the optical power and wavelength of a laser source. A wide variety of measurement heads cover wavelength ranges from 350 to 1650 nm for power ranges of up to +40dBm or 10W.This meter has standard features such as logarithmic or linear display modes, auto ranging, user calibratable offset, reference measurement capability, analog output and IEEE-standard GPIB interface to make this instrument a cost effective laser diode development or production test tool.